Gallery of Lights


Home Login
Album list Last uploads Last comments Most viewed Top rated My Favorites Search
Home > User galleries > Lil'Cinnamon > My Lights

Last comments - My Lights
DSCN0951.JPG
Brand new M-400 A2!114 views9 commentsLil'Cinnamon03/09/11 at 08:12joe_347V: I'm guessing you could like what Devonte said,...
DSCN0951.JPG
Brand new M-400 A2!114 views9 commentsLil'Cinnamon03/09/11 at 04:35Form109: can't you order one from GE?
DSCN0011.jpg
Underside of the M-250r2.102 views10 commentsLil'Cinnamon03/03/11 at 22:27streetlight98: I could tell it was a Phillips 'cause of the g...
DSCN0006.jpg
M-250r2 mounted. Yardblaster in Background.109 views14 commentsLil'Cinnamon03/02/11 at 19:27gailgrove: I think its a good setup other then the wiring Very Happy
DSCN0013.jpg
M-250r2 mouted and open.97 views23 commentsLil'Cinnamon03/02/11 at 19:25LilCinnamon: Well the yardblaster ballast kind of used wirenuts...
DSCN0009.jpg
NEMA head mounted.83 views2 commentsLil'Cinnamon03/02/11 at 15:59GullWhiz: It's actually mounted very nicely! The model i...
DSCN0013.jpg
M-250r2 mouted and open.97 views23 commentsLil'Cinnamon03/02/11 at 15:50GullWhiz: Internals looks acceptable, one important thing is...
DSCN0013.jpg
M-250r2 mouted and open.97 views23 commentsLil'Cinnamon03/02/11 at 06:58LilCinnamon: OTHER than the wiring, How is the internals of the...
DSCN0011.jpg
Underside of the M-250r2.102 views10 commentsLil'Cinnamon03/02/11 at 06:58LilCinnamon: Phillips ALTO from The Home Depot.

And the NEMA...
DSCN0006.jpg
M-250r2 mounted. Yardblaster in Background.109 views14 commentsLil'Cinnamon03/02/11 at 06:53LilCinnamon: Other than the Tacky WIRING, how is the setup and ...
DSCN0013.jpg
M-250r2 mouted and open.97 views23 commentsLil'Cinnamon03/02/11 at 04:56Form109: if for no other reason than just that....its a gas...
DSCN0013.jpg
M-250r2 mouted and open.97 views23 commentsLil'Cinnamon03/02/11 at 03:36GullWhiz: Just a quick tip....NEVER use gas pipes as a groun...
DSCN0013.jpg
M-250r2 mouted and open.97 views23 commentsLil'Cinnamon03/02/11 at 02:41TiCoune66: Ah you connect to BOTH? Interesting. Over here the...
DSCN0013.jpg
M-250r2 mouted and open.97 views23 commentsLil'Cinnamon03/02/11 at 02:18GullWhiz: Most cases in the USA we have one ground rod bonde...
DSCN0013.jpg
M-250r2 mouted and open.97 views23 commentsLil'Cinnamon03/02/11 at 01:48TiCoune66: Well there are a few cases where can absolutely no...
DSCN0013.jpg
M-250r2 mouted and open.97 views23 commentsLil'Cinnamon03/02/11 at 01:39GullWhiz: Also a grounding rod is to be properly straight do...
DSCN0013.jpg
M-250r2 mouted and open.97 views23 commentsLil'Cinnamon03/02/11 at 00:51TiCoune66: A grounding rod is more than 10ft long!

BTW, yo...
DSCN0013.jpg
M-250r2 mouted and open.97 views23 commentsLil'Cinnamon03/02/11 at 00:38GullWhiz: No you can't really do that.....it's not t...
DSCN0013.jpg
M-250r2 mouted and open.97 views23 commentsLil'Cinnamon03/01/11 at 22:17streetlight98: Just run a wire from the fixture casing to the gro...
DSCN0011.jpg
Underside of the M-250r2.102 views10 commentsLil'Cinnamon03/01/11 at 22:14streetlight98: Using a Phillips lamp? What's the NEMA label m...
DSCN0009.jpg
NEMA head mounted.83 views2 commentsLil'Cinnamon03/01/11 at 22:14streetlight98: Nice. Cool
DSCN0016.jpg
Closeup of Slipfitter 83 views12 commentsLil'Cinnamon03/01/11 at 02:49TiCoune66: Well I know that most XLPE-insulated wires (like X...
DSCN0016.jpg
Closeup of Slipfitter 83 views12 commentsLil'Cinnamon03/01/11 at 02:45GullWhiz: Yes that is correct.....the liquidtight flex is th...
DSCN0016.jpg
Closeup of Slipfitter 83 views12 commentsLil'Cinnamon03/01/11 at 01:44joe_347V: I'm not sure but I THINK that THWN wires in li...
DSCN0016.jpg
Closeup of Slipfitter 83 views12 commentsLil'Cinnamon02/28/11 at 21:34GullWhiz: Vince...you are right....duh me on that....and you...
2470 files on 99 page(s) 90