New project: Dividing my original circuit for my shelf in two circuits.175 viewsVince06/25/13 at 23:42joe_347V: Well, fuses blow at overcurrent hence the term slo...
|
|
New project: Dividing my original circuit for my shelf in two circuits.175 viewsVince06/25/13 at 23:40GEsoftwhite100watts: Here the slow-blow ones are called "time-dela...
|
|
New project: Dividing my original circuit for my shelf in two circuits.175 viewsVince06/25/13 at 23:25joe_347V: They make a lot more than that...
To name a few...
|
|
New project: Dividing my original circuit for my shelf in two circuits.175 viewsVince06/25/13 at 23:22GEsoftwhite100watts: And replacement 15A fuses are still made, I see th...
|
|
New project: Dividing my original circuit for my shelf in two circuits.175 viewsVince06/25/13 at 23:19joe_347V: Probably sometime during the mid-early 60s when br...
|
|
New project: Dividing my original circuit for my shelf in two circuits.175 viewsVince06/25/13 at 23:12GEsoftwhite100watts: Thanks...when did they phase out cartridge fuses a...
|
|
New project: Dividing my original circuit for my shelf in two circuits.175 viewsVince06/25/13 at 23:07joe_347V: Fused disconnects are still made... The ones from ...
|
|
New project: Dividing my original circuit for my shelf in two circuits.175 viewsVince06/25/13 at 23:05GEsoftwhite100watts: Is i just me or do some older breakers snap more l...
|
|
New project: Dividing my original circuit for my shelf in two circuits.175 viewsVince06/25/13 at 22:52joe_347V: Older non-mercury switches had a snap action like ...
|
|
New project: Dividing my original circuit for my shelf in two circuits.175 viewsVince06/25/13 at 22:41streetlight98: yeaah arcing is an issue with newer switches that ...
|
|
New project: Dividing my original circuit for my shelf in two circuits.175 viewsVince06/25/13 at 22:33GEsoftwhite100watts: Basically from what I understand the idea behind m...
|
|
New project: Dividing my original circuit for my shelf in two circuits.175 viewsVince06/25/13 at 22:12streetlight98: ahh i thought all switches here like that?
|
|
New project: Dividing my original circuit for my shelf in two circuits.175 viewsVince06/25/13 at 21:29joe_347V: Mercury switches are different, they're regula...
|
|
New project: Dividing my original circuit for my shelf in two circuits.175 viewsVince06/24/13 at 20:53streetlight98: oh i've seen the toggles in the hotel i stayed...
|
|
New project: Dividing my original circuit for my shelf in two circuits.175 viewsVince06/24/13 at 20:36joe_347V: They're switches with a built in neon pilot li...
|
|
New project: Dividing my original circuit for my shelf in two circuits.175 viewsVince06/24/13 at 20:11streetlight98: what are neon switches?
|
|
New project: Dividing my original circuit for my shelf in two circuits.175 viewsVince06/24/13 at 18:58joe_347V: I think the 2-pole 30A fused disconnects sold for ...
|
|
Finds of the day! - 06/07/2013185 viewsVince06/24/13 at 18:52joe_347V: They're sorta common in Canada but you'll ...
|
|
New project: Dividing my original circuit for my shelf in two circuits.175 viewsVince06/24/13 at 13:37streetlight98: fuse boxes aren't allowed in new construction ...
|
|
Fuses!141 viewsVince06/24/13 at 10:31migette1: I really must show my continental fuse box used in...
|
|
It's working!!135 viewsVince06/24/13 at 10:22migette1: Nice unit there, when these turn up here its the l...
|
|
New project: Dividing my original circuit for my shelf in two circuits.175 viewsVince06/24/13 at 10:12migette1: Are these still used, remember these in the 50s as...
|
|
Finds of the day! - 06/07/2013185 viewsVince06/24/13 at 09:23migette1: Are these places common in Canada, I know a friend...
|
|
York 2 X F40 troffer now in service!128 viewsVince06/23/13 at 00:11GEsoftwhite100watts: Was '05 when they switched to Ecolux? If so is...
|
|
Westinghouse Lumiline 40W white lamps, virtually NOS!6042 viewsVince06/18/13 at 02:54joe_347V: These should run on straight 120v.
Interestingl...
|
|