Another Shot of the Ballast
Keywords: American_Streetlights

Another Shot of the Ballast

gol101314_029.JPG gol101314_031.JPG gol082014_014.JPG ov151.jpg ov155.jpg
File information
Filename:ov155.jpg
Album name:Mike / My Westinghouse OV-15TD TuDor
Keywords:American_Streetlights
Filesize:79 KiB
Date added:Dec 21, 2013
Dimensions:640 x 480 pixels
Displayed:146 times
Color Space:sRGB
DateTime Original:0000:00:00 00:00:00
Exposure Bias:0 EV
Exposure Program:Program
Exposure Time:1/1000 sec
FNumber:f/4
Flash:No Flash
Focal length:4.5 mm
ISO:100
Light Source:Unknown: 0
Make:Olympus Optical Co.,ltd
Max Aperture:f/4
Model:C120,D380
URL:http://www.galleryoflights.org/mb/gallery/displayimage.php?pid=16745
Favorites:Add to Favorites

Comment 1 to 7 of 7
Page: 1

streetlight98   [Jul 23, 2014 at 09:11 PM]
BTW, anyone know if the cap is necessary with this reactor ballast? Also, if the cap is not needed, would the ballast be wired like a normal NPF reactor or are the two capacitor wires connected together?
A_lights   [Jul 23, 2014 at 10:25 PM]
If the cap isn't needed cap the wires off individual for the cap
streetlight98   [Jul 24, 2014 at 03:03 AM]
ahh so the capacitor wires are capped separately? This is a HPF reactor but the capacitor terminals are rotted out and the cap is bad. Would a bad cap in this cause cause the fixture not to work? If the cap isn't needed I won't bother getting a new one, though I'll keep that one in there (disconnected).
joe_347V   [Jul 24, 2014 at 05:16 PM]
Yeah you cap them individually or better you can rewire the reactor like a NPF one so you can get rid of the cap leads.
streetlight98   [Jul 24, 2014 at 07:26 PM]
How would I rewire it? If I can make out what the cap info is on the ballast tag then I will leave the cap wires in there and just tape over the slip-on connectors so that when I get around to getting a capacitor I can just put it in. I will leave the old cap in place just as a placeholder.

Not positive, but I think the fixture's nameplate is gone. All that's left is the ballast label. Fortunately they used ballast labels; GE did not use them, though they did put an additional nameplate on their Powr/Modules. Doesn't look like Westinghouse did that...
joe_347V   [Jul 25, 2014 at 12:16 AM]
HPS reactor ballasts are fairly straightforward to rewire. You simply get rid of the wire that led to the cap at the hot wire and the neutral. I suppose capping the wires also works lol.
streetlight98   [Jul 25, 2014 at 12:50 AM]
Ahh OK. you said rewire it and made it sound like a big production. Razz Nah i guess I'll just leave the wires in there with the slip-on connectors wrapped in tape so they're insulated (that way I don't need to waste a pair of slip-on crimps if I get a new cap lol). I didn't know if the cap leads connected affected the operation of the ballast.