CGE 17A240E1 Gold Label
Here is a newer Gold Label ballast from March 1988, slightly different from [url=http://www.galleryoflights.org/mb/gallery/displayimage.php?pos=-963]this earlier model from 1983[/url]. It has been removed from a York troffer because of its odd model number. For some reason there's a 1 after the E. I've never seen something being added after the last letter of CGE's ballast model numbers.

That letter first indicated which sort of thermal protection came with the ballast. An N indicated a non-resetting thermal protection while an A indicated an automatic resetting protection. Those two suffixes have been used until the early 70s, by that time they were replaced by the T, which probably designated the thermal protection, non-resetting thermal protections having been likely phased out.

In the mid-late 70s, CGE created a separate line of non-OEM ballasts intended for sale as replacement ballasts. Those ballast were given the suffix W and had an extra warranty period, 6 months first, then 1 year in the 80s. [url=http://www.galleryoflights.org/mb/gallery/displayimage.php?pos=-5500]Here's an example of one (bottom ballast)[/url].

Then CGE redesigned their ballast labels, probably in the same time they introduced the framed CGE meatball logo. All the previous suffixes have been phased out and replaced by the E, which means the ballast doesn't contain any PCBs. It has been suggested the E would mean Ecologic, or Environment, this still has to be confirmed.

That pretty much what I know of those suffixes at the moment. The purpose of the 1 on the ballast pictured above is still unknown to me.
Keywords: Gear

CGE 17A240E1 Gold Label

Here is a newer Gold Label ballast from March 1988, slightly different from this earlier model from 1983. It has been removed from a York troffer because of its odd model number. For some reason there's a 1 after the E. I've never seen something being added after the last letter of CGE's ballast model numbers.

That letter first indicated which sort of thermal protection came with the ballast. An N indicated a non-resetting thermal protection while an A indicated an automatic resetting protection. Those two suffixes have been used until the early 70s, by that time they were replaced by the T, which probably designated the thermal protection, non-resetting thermal protections having been likely phased out.

In the mid-late 70s, CGE created a separate line of non-OEM ballasts intended for sale as replacement ballasts. Those ballast were given the suffix W and had an extra warranty period, 6 months first, then 1 year in the 80s. Here's an example of one (bottom ballast).

Then CGE redesigned their ballast labels, probably in the same time they introduced the framed CGE meatball logo. All the previous suffixes have been phased out and replaced by the E, which means the ballast doesn't contain any PCBs. It has been suggested the E would mean Ecologic, or Environment, this still has to be confirmed.

That pretty much what I know of those suffixes at the moment. The purpose of the 1 on the ballast pictured above is still unknown to me.

100_1127.jpg 100_1125.jpg HPIM0646.JPG 20120904_192419.jpg 100_0884.jpg
File information
Filename:HPIM0646.JPG
Album name:Vince / All my ballasts
Keywords:Gear
Company and Date Manufactured:Canadian General Electric | March 1988
Model Number:17A240E1
Wattage:2 X 40W
Lamp Type:Fluorescent
Filesize:830 KiB
Date added:Mar 01, 2012
Dimensions:2592 x 1944 pixels
Displayed:229 times
Color Space:sRGB
Contrast:0
DateTime Original:2012:02:27 20:46:52
Exposure Bias:0 EV
Exposure Mode:0
Exposure Program:Program
Exposure Time:10/1199 sec
FNumber:f/3.6
Flash:No Flash
Focal length:7.5 mm
ISO:182
Light Source:Unknown: 0
Make:Hewlett-packard
Max Aperture:f/3
Model:HP DVC V5061u
URL:http://www.galleryoflights.org/mb/gallery/displayimage.php?pid=10933
Favorites:Add to Favorites

Comment 1 to 1 of 1
Page: 1

joe_347V   [Mar 01, 2012 at 11:41 PM]
Hmm I read from the PCB ballast guide (pg 3) that the E suffix does indeed stand for environmental. Anyways nice ballast!