Arrow Preheat Shoplight Insides
Special thanks to Mike for this light.  I believe the ballast (old Ad-Lite) is original.  
Keywords: Indoor_Fixtures

Arrow Preheat Shoplight Insides

Special thanks to Mike for this light. I believe the ballast (old Ad-Lite) is original.

20180508_175623[1].jpg floodlights.jpg IMG_3693.JPG IMG_3694.JPG IMG_3696.JPG
File information
Filename:IMG_3693.JPG
Album name:GEsoftwhite100watts / Indoor Fixtures
Keywords:Indoor_Fixtures
Company and Date Manufactured:Arrow, 1950's?
Filesize:627 KiB
Date added:Apr 21, 2018
Dimensions:3000 x 2250 pixels
Displayed:166 times
URL:http://www.galleryoflights.org/mb/gallery/displayimage.php?pid=23034
Favorites:Add to Favorites

Comment 1 to 4 of 4
Page: 1

streetlight98   [Apr 21, 2018 at 09:51 PM]
No problem, Andy! Smile Yes the ballast is 100% original! I replaced the wires for the starter circuits and pull chain but the ballast leads were in decent shape so they were kept as-is. Added the inline 1A fuse too just in case anything goes haywire with the ballast. Any fixture I've gotten with a dead AdLite had had a passive failure though, so hopefully there's nothing to worry about.
GEsoftwhite100watts   [Apr 21, 2018 at 10:16 PM]
Yeah, your story about having a similar fixture burn up overnight once should be required reading for anybody into anything this old. Laughing
streetlight98   [Apr 21, 2018 at 11:04 PM]
Haha! Yeah it was a pretty scary experience. The extra couple bucks it takes to fuse the light is well worth the peace of mind it brings. Although the ballast may not draw enough extra current to trip the fuse in all modes of catastrophic failure, it should at least help limit the damage. I use 1A fuses in all my fused 2X F40T12 lights (and I only fuse the older ones without thermal protection, so they're mostly rated 0.8 or 0.85 amps) so it's a pretty close match. I suspect that if I went any lower I might experience nuisance fuse burnouts. General rule of thumb is loading a breaker or fuse to 80% of tripping capacity so at 0.8A, a 1A fuse is perfect following that logic.
GEsoftwhite100watts   [Apr 22, 2018 at 04:56 AM]
Unless, of course, you're on Federal-Pacific circuit breakers, where that doesn't apply. Laughing

Sentry in Fairbanks still has some of those fire-hazard aboninitions in stock! Shocked